If the TS1162 is the last device on a long RS-485 cable run, set the termination DIP switch (typically Switch 8) to the 'ON' position to prevent data signal reflections. 4. System Integration
Ensure the mounting surface allows the rear tamper lever to be fully depressed when the unit is secured. Enclosure Removal: Undo the retaining screws at the bottom of the keypad. ts1162 installation manual
The is a 3-LED Remote Arming Station (RAS) designed for use with Challenger security systems. Rated at IP67 , this robust keypad is suitable for both indoor and outdoor installations, including harsh, dusty, or wet environments. If the TS1162 is the last device on
Use the base as a template to mark screw holes. Use appropriate fasteners for the mounting surface (e.g., wall plugs for masonry). 2. Wiring and Terminals Enclosure Removal: Undo the retaining screws at the
Pull the bottom of the body away from the base and lift it off the top tabs.
The Challenger system identifies each keypad by its unique RAS address, which must be set manually before the unit is powered up.
Choose a flat, solid, vertical surface to prevent the base from warping when tightened.